Browse by author
Lookup NU author(s): Dr Zhongxu Hu, Dr Barry Gallacher, Emeritus Professor James Burdess
Full text for this publication is not currently held within this repository. Alternative links are provided below where available.
This paper reports the experimental results of parametric amplification applied to a harmonically forced MEMS gyroscope. Parametric amplification of the forced response at resonance in the range 10-100 is investigated. Several important factors pertinent to practical exploitation are highlighted. The main obstacle to high gain parametric amplification is the nonlinearity of the electrostatic force which becomes significant for high amplitude vibration. By significantly reducing the harmonic forcing level to just above the noise threshold, parametric amplification of the resonant response by a factor of 80 has been achieved whilst maintaining linear response characteristics. © 2009.
Author(s): Hu Z, Gallacher B, Harish K, Burdess J
Publication type: Article
Publication status: Published
Journal: Procedia Chemistry
Year: 2009
Volume: 1
Issue: 1
Pages: 112-115
ISSN (electronic): 1876-6196
Publisher: Elsevier BV
URL: http://dx.doi.org/10.1016/j.proche.2009.07.028
DOI: 10.1016/j.proche.2009.07.028
Altmetrics provided by Altmetric