The principle of the inductance displacement sensor on optical aperture synthesis telescope is given with a measurement of mutual inductance to deduce the axial distance. It illustrates an effective modelling and calculation method based on Partial Element Equivalent Circuit (PEEC). PEEC is the method to calculate mutual inductances between coils utilizing partial parameter concept. Simulation for the change of mutual inductances is done which is prepared for the next step work.
Author(s): Wang HT, Luo QF, Cai JH, Zhang YJ, Wan JW, Zhu YK, Tian GY
Publication type: Conference Proceedings (inc. Abstract)
Publication status: Published
Conference Name: International Journal of Applied Electromagnetics and Mechanics: 14th International Symposium on Applied Electromagnetics and Mechanics (ISEM)
Year of Conference: 2010
Pages: 613-620
ISSN: 1383-5416
Publisher: IOS Press
URL: http://dx.doi.org/10.3233/JAE-2010-1165
DOI: 10.3233/JAE-2010-1165
Library holdings: Search Newcastle University Library for this item
ISBN: 18758800