Extracting fetal heart beats from maternal abdominal recordings: selection of the optimal principal components

Lookup NU author(s): Costanzo Di Maria, Dr Chengyu Liu, Dr Ding Chang Zheng, Emeritus Professor Alan MurrayORCiD, Dr Philip Langley

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

This study presents a systematic comparison of different approaches to the automated selection of the principal components (PC) which optimise the detection of maternal and fetal heart beats from non-invasive maternal abdominal recordings.A public database of 75 4-channel non-invasive maternal abdominal recordings was used for training the algorithm. Four methods were developed and assessed to determine the optimal PC: (1) power spectral distribution, (2) root mean square, (3) sample entropy, and (4) QRS template. The sensitivity of the performance of the algorithm to large-amplitude noise removal (by wavelet de-noising) and maternal beat cancellation methods were also assessed. The accuracy of maternal and fetal beat detection was assessed against reference annotations and quantified using the detection accuracy score F1 [2*PPV*Se /(PPV + Se)], sensitivity (Se), and positive predictive value (PPV). The best performing implementation was assessed on a test dataset of 100 recordings and the agreement between the computed and the reference fetal heart rate (fHR) and fetal RR (fRR) time series quantified.The best performance for detecting maternal beats (F1 99.3%, Se 99.0%, PPV 99.7%) was obtained when using the QRS template method to select the optimal maternal PC and applying wavelet de-noising. The best performance for detecting fetal beats (F1 89.8%, Se 89.3%, PPV 90.5%) was obtained when the optimal fetal PC was selected using the sample entropy method and utilising a fixed-length time window for the cancellation of the maternal beats. The performance on the test dataset was 142.7 beats(2)/min(2) for fHR and 19.9 ms for fRR, ranking respectively 14 and 17 (out of 29) when compared to the other algorithms presented at the Physionet Challenge 2013.


Publication metadata

Author(s): Di Maria C, Liu CY, Zheng DC, Murray A, Langley P

Publication type: Article

Publication status: Published

Journal: Physiological Measurement

Year: 2014

Volume: 35

Issue: 8

Pages: 1649-1664

Print publication date: 01/08/2014

Online publication date: 28/07/2014

Acceptance date: 30/06/2014

ISSN (print): 0967-3334

ISSN (electronic): 1361-6579

Publisher: Institute of Physics Publishing Ltd.

URL: http://dx.doi.org/10.1088/0967-3334/35/8/1649

DOI: 10.1088/0967-3334/35/8/1649


Altmetrics

Altmetrics provided by Altmetric