Browse by author
Lookup NU author(s): Dr Mohaned Egred
Full text for this publication is not currently held within this repository. Alternative links are provided below where available.
OBJECTIVES The study sought to investigate the relationship between post-procedural asymmetry, expansion, and eccentricity indices of metallic everolimus-eluting stent (EES) and bioresorbable vascular scaffold (BVS) and their respective impact on clinical events at 1-year follow-up.BACKGROUND Mechanical properties of a fully BVS are inherently different from those of permanent metallic stent.METHODS The ABSORB II (A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions) trial compared the BVS and metallic EES in the treatment of a de novo coronary artery stenosis. Protocol-mandated intravascular ultrasound imaging was performed pre-and post-procedure in 470 patients (162 metallic EES and 308 BVS). Asymmetry index (AI) was calculated per lesion as: (1 - minimum scaffold/stent diameter/maximum scaffold/stent diameter). Expansion index and optimal scaffold/ stent expansion followed the definition of the MUSIC (Multicenter Ultrasound Stenting in Coronaries) study. Eccentricity index (EI) was calculated as the ratio of minimum and maximum scaffold/stent diameter per cross section. The incidence of device-oriented composite endpoint (DoCE) was collected.RESULTS Post-procedure, the metallic EES group was more symmetric and concentric than the BVS group. Only 8.0% of the BVS arm and 20.0% of the metallic EES arm achieved optimal scaffold/stent expansion (p < 0.001). At 1 year, there was no difference in the DoCE between both devices (BVS 5.2% vs. EES 3.1%; p = 0.29). Post-procedural devices asymmetry and eccentricity were related to higher event rates while there was no relevance to the expansion status. Subsequent multivariate analysis identified that post-procedural AI > 0.30 is an independent predictor of DoCE (hazard ratio: 3.43; 95% confidence interval: 1.08 to 10.92; p = 0.037).CONCLUSIONS BVS implantation is more frequently associated with post-procedural asymmetric and eccentric morphology compared to metallic EES. Post-procedural devices asymmetry were independently associated with DoCE following percutaneous coronary intervention. However, this approach should be viewed as hypothesis generating due to low event rates. (C) 2016 by the American College of Cardiology Foundation.
Author(s): Suwannasom P, Sotomi Y, Ishibashi Y, Cavalcante R, Albuquerque FN, Macaya C, Ormiston JA, Hill J, Lang IM, Egred M, Fajadet J, Lesiak M, Tijssen JG, Wykrzykowska JJ, de Winter RJ, Chevalier B, Serruys PW, Onuma Y
Publication type: Article
Publication status: Published
Journal: JACC: Cardiovascular Interventions
Year: 2016
Volume: 9
Issue: 12
Pages: 1231-1242
Print publication date: 27/06/2016
Online publication date: 01/06/2016
Acceptance date: 24/03/2016
ISSN (print): 1936-8798
ISSN (electronic): 1876-7605
Publisher: Elsevier
URL: http://dx.doi.org/10.1016/j.jcin.2016.03.027
DOI: 10.1016/j.jcin.2016.03.027
Altmetrics provided by Altmetric