Browse by author
Lookup NU author(s): Dr Moloy Das
Full text for this publication is not currently held within this repository. Alternative links are provided below where available.
Background Catheter ablation for persistent atrial fibrillation (AF) is associated with less favorable outcomes than for paroxysmal AF. Substrate modification is often added to pulmonary vein isolation (PVI) to try to improve success rates. Recent studies have shown improved clinical outcomes with use of regional ablation index (AI) targets for PVI. We hypothesized that prospective use of AI-guided PVI in persistent AF patients would result in a low rate of PV reconnection at repeat electrophysiology study and that a high success rate can be achieved with durable PVI alone. Methods Forty consecutive patients with persistent AF underwent AI-guided PVI with target values of 550 for anterior and 400 for posterior left atrial regions, followed by a protocol-mandated repeat procedure after 2 months. Patients were monitored for atrial tachyarrhythmia recurrence via daily plus symptom-initiated ECG recordings for 12 months. Recurrence was defined as ≥30 seconds of any atrial tachyarrhythmia after a 3-month blanking period. Results PV reconnection was seen at repeat electrophysiology study in 22% of patients, affecting 7% of PVs. Ablation on the intervenous carina was required in 44% patients to achieve durable PVI. Atrial tachyarrhythmia recurrence was documented in 8 (20%) patients, only one of whom had PV reconnection at repeat study. At 12 months, 38/40 (95%) patients were in sinus rhythm, with 4 (10%) patients having started antiarrhythmic drugs. Higher body mass index and excess alcohol consumption were the only significant factors associated with atrial tachyarrhythmia recurrence. Conclusions Use of AI targets results in a high level of durable PVI. A good clinical outcome can be achieved in the great majority of persistent AF patients with AI-guided PVI alone. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT02628730.
Author(s): Hussein A, Das M, Riva S, Morgan M, Ronayne C, Sahni A, Shaw M, Todd D, Hall M, Modi S, Natale A, Dello Russo A, Snowdon R, Gupta D
Publication type: Article
Publication status: Published
Journal: Circulation: Arrhythmia and Electrophysiology
Year: 2018
Volume: 11
Issue: 9
Online publication date: 14/09/2018
Acceptance date: 02/04/2018
ISSN (print): 1941-3149
ISSN (electronic): 1941-3084
Publisher: Lippincott Williams & Wilkins
URL: https://doi.org/10.1161/CIRCEP.118.006576
DOI: 10.1161/CIRCEP.118.006576
PubMed id: 30354288
Altmetrics provided by Altmetric