© 2018 Background and Aims Distal attachments placed on the colonoscope tip may positively affect performance by assisting insertion and polyp detection. The original Endocuff (ARC Medical Design, Leeds, United Kingdom) appears to improve adenoma detection rate (ADR), but no data assess the performance of the second-generation Endocuff Vision. Methods A pilot service evaluation study (April 2013 to September 2014) was conducted on patients with positive fecal occult blood tests within the National Bowel Cancer Programme during 3 consecutive periods: precuff/no device used, during-cuff/device used, and postcuff/no device used. During the middle period the use of the Endocuff Vision by the 4 screening-accredited colonoscopists was discretional (nonrandomized design). Data were analyzed using pairwise comparisons during the 3 designated periods to examine key performance indicators: adenoma detection, procedural time, sedation requirements, and patient comfort. Results Four hundred ten complete colonoscopies were performed (137 precuff, 136 cuff, and 137 postcuff period). Overall, there was a notable increase in the mean ADR of 16% (P <.03) and in the mean number adenoma per procedure (MAP) of 83% (P =.007) from precuff to cuff period. The mean cecal intubation time was statistically lower during the cuff period (7 minutes) in relation to the precuff period (8 minutes; reduction of 12.5%, P =.002) and the postcuff period (9 minutes; increase of 28.6%, P =.002). The mean negative colonoscopy withdrawal time was also significantly lower during the cuff period (8 minutes, 30 seconds) when compared with the precuff (12 minutes) or postcuff period (9 minutes, 45 seconds; P ≤.001). Multivariate regression analysis showed that the use of the Endocuff Vision was not associated with sedation requirements or patient discomfort scores. No adverse events were reported from the use of the Endocuff Vision, although it was electively removed in 6 patients where severe sigmoid colon diverticulosis was encountered and 2 patients because of discomfort during anal insertion. Conclusions In this pilot service evaluation study, the use of the Endocuff Vision appears to be associated with an improvement in overall colonoscopy operator performance. We found increased ADR and MAP as well as decreased time for colonoscope insertion and withdrawal time with no increase in sedation requirements or patient discomfort.
Author(s): Tsiamoulos ZP, Misra R, Rameshshanker R, Elliott TR, Beintaris I, Thomas-Gibson S, Haycock A, Suzuki N, Rees C, Saunders BP
Publication type: Article
Publication status: Published
Journal: Gastrointestinal Endoscopy
Year: 2017
Volume: 87
Issue: 1
Pages: 280-287
Print publication date: 01/01/2018
Online publication date: 13/04/2017
Acceptance date: 03/04/2017
ISSN (print): 0016-5107
ISSN (electronic): 1097-6779
Publisher: Mosby Inc.
URL: https://doi.org/10.1016/j.gie.2017.04.001
DOI: 10.1016/j.gie.2017.04.001
PubMed id: 28412271
Altmetrics provided by Altmetric