The Newcastle University research output collection, currently available on ePrints, will shortly be moving to a new open repository platform, Figshare. To prepare for the data migration we have paused adding new content to ePrints, and will resume once the new repository is launched. During this time you will continue to have access to ePrints (but no new content will appear). We will share updates here when available.

Sustained colonoscopy quality improvement using a simple intervention bundle

Lookup NU author(s): Dr Laura Neilson, Dr Roisin Bevan, Professor Colin ReesORCiD

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

© Georg Thieme Verlag KG Stuttgart · New York. BACKGROUND: Unacceptable variation in colonoscopy quality exists. The Quality Improvement in Colonoscopy (QIC) study in 2011 improved quality by introducing an evidence-based "bundle" of measures into routine colonoscopy practice. The QIC bundle included: minimal cecal withdrawal time of ≥ 6 minutes; hyoscine butylbromide use; supine patient position for transverse colon examination; rectal retroflexion. Colonoscopy quality was measured by adenoma detection rate (ADR). The current study measured whether these effects led to a sustained change in practice 3 years following implementation. METHODS: This observational study collected data from eight hospital trusts (sites) in the United Kingdom for a 6-month period, 3 years following QIC bundle implementation. Use of the antispasmodic, hyoscine butylbromide, was measured as a marker of bundle uptake. Bundle effectiveness was measured by ADR change. Comparisons were made between data before and immediately after implementation of the bundle. RESULTS: 28 615 colonoscopies by 188 colonoscopists were studied. Hyoscine butylbromide use increased from 15.8 % pre-implementation to 47.4 % in the sustainability phase (P < 0.01) indicating sustained engagement with QIC measures. ADR was higher in the sustainability period compared with pre-intervention, but only reached statistical significance among the poorest-performing colonoscopists. CONCLUSIONS: The introduction of a simple, inexpensive, pragmatic intervention significantly changed practice over a sustained period, improving colonoscopy quality as measured by ADR, particularly in poorer performers. QIC demonstrates that an easy-to-implement quality improvement approach can deliver a sustained change in practice for many years post intervention.


Publication metadata

Author(s): Neilson LJ, East JE, Rajasekhar PT, Bassett P, Dunn S, Bevan R, Paremal S, Esmaily S, Rees CJ

Publication type: Article

Publication status: Published

Journal: Endoscopy

Year: 2020

Volume: 52

Issue: 4

Pages: 285-292

Print publication date: 01/04/2020

Online publication date: 02/03/2020

Acceptance date: 16/12/2019

ISSN (print): 0013-726X

ISSN (electronic): 1438-8812

Publisher: Georg Thieme Verlag

URL: https://doi.org/10.1055/a-1098-2101

DOI: 10.1055/a-1098-2101

PubMed id: 32120412


Altmetrics

Altmetrics provided by Altmetric


Share