Toggle Main Menu Toggle Search

Open Access padlockePrints

Ceramic Bearings Are Associated With a Significantly Reduced Revision Rate in Primary Hip Arthroplasty: An Analysis From the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man

Lookup NU author(s): Dr Richard Holleyman, Professor James Mason, Dr Simon Jameson, Ajay MalviyaORCiD

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

Copyright © 2021 Elsevier Inc. All rights reserved. BACKGROUND: Prosthetic joint infection (PJI) is a devastating complication. Studies have suggested reduction in PJI with the use of ceramic bearings. METHODS: Adult patients who underwent total hip arthroplasty (THA) using an uncemented acetabular component with ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), or metal-on-polyethylene (MoP) bearing surfaces between 2002 and 2016 were extracted from the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. A competing risk regression model to investigate predictors of each revision outcome was used. Time-to-event was determined by duration of implantation since primary surgery with competing risks being death or revision. The results were adjusted for age, gender, American Association of Anaesthesiologists grade, body mass index, surgical indication, intraoperative complications, and implant data. RESULTS: In total, 456,457 THAs (228,786 MoP, 128,403 CoC, and 99,268 CoP) were identified. Multivariable modeling showed that the risk of revision for PJI was significantly lower with CoC (risk ratio 0.748, P < .001) and CoP (risk ratio 0.775, P < .001) compared to MoP. Significant reduction in risk of aseptic and all-cause revision was also seen. The significant protective effect of ceramic bearing was predominantly seen 2 years after implantation. Aseptic revision beyond 2 years reduced by 18.1% and 24.8% for CoC and CoP (P < .001), respectively. All-cause revision rate beyond 2 years reduced by 21.6% for CoC and 27.1% for CoP (P < .001) CONCLUSION: This study demonstrates an association between the use of ceramic as part of the bearing, with lower rates of revision for all causes, revision for infection, and revision for aseptic causes, supporting ceramic bearings in THA.


Publication metadata

Author(s): Holleyman RJ, Critchley RJ, Mason JM, Jameson SS, Reed MR, Malviya A

Publication type: Article

Publication status: Published

Journal: Journal of Arthroplasty

Year: 2021

Volume: 36

Issue: 10

Pages: 3498-3506

Print publication date: 01/10/2021

Online publication date: 15/06/2021

Acceptance date: 13/05/2021

ISSN (print): 0883-5403

ISSN (electronic): 1532-8406

Publisher: Elsevier Inc.

URL: https://doi.org/10.1016/j.arth.2021.05.027

DOI: 10.1016/j.arth.2021.05.027

PubMed id: 34238620


Altmetrics

Altmetrics provided by Altmetric