Browse by author
Lookup NU author(s): Dr Fiona Smith, Dr Philip Langley, Dr John Bourke, Emeritus Professor Alan MurrayORCiD
Full text for this publication is not currently held within this repository. Alternative links are provided below where available.
Multichannel magnetocardiography measures the magnetic field distribution of the human heart noninvasively from many sites over the body surface. Multichannel magnetocardiogram. (MCG) analysis enables regional temporal differences in the distribution of cardiac magnetic field strength during depolarization and repolarization to be identified, allowing estimation of the global and local inhomogeneity of the cardiac activation process. he aim of this study was to compare the spatial distribution of cardiac magnetic field strength during ventricular depolarization and repolarization in both normal subjects and patients with cardiac abnormalities, obtaining amplitude measurements by magnetocardiography. MCGs were recorded at 49 sites over the heart from three normal subjects and two patients with inverted T-wave conditions. The magnetic field intensity during depolarization and repolarization was measured automatically for each channel and displayed spatially as contour maps. A Pearson correlation was used to determine the spatial relationship between the variables. For normal subjects, magnetic field strength maps during depolarization (R-wave) showed two asymmetric regions of magnetic field strength with a high positive value in the lower half of the chest and a high negative value above this. The regions of high R-wave amplitude corresponded spatially to concentrated asymmetric regions of high magnetic field strength during repolarization (T-wave). Pearson-r correlation coefficients of 0.7 (p < 0.01), 0.8 (p < 0.01) and 0.9 (p < 0.01) were obtained from this analysis for the three normal subjects. A negative correlation coefficient of -0.7 (p < 0.01) was obtained for one of the subjects with inverted T-wave abnormalities, suggesting similar but inverted magnetic field and current distributions to normal subjects. Even with the high correlation values in these four subjects, the MCG was able to identify differences in the distribution of magnetic field strength, with a shift in the T-wave relative to the R-wave. The measurement of cardiac magnetic field distribution during depolarization and repolarization of normal subjects and patients with clinical abnormalities should enable the improvement of theoretical models for the explanation of the cardiac depolarization and repolarization processes.
Author(s): Smith FE, Langley P, Trahms L, Steinhoff U, Bourke JP, Murray A
Publication type: Article
Publication status: Published
Journal: International Journal of Bifurcation and Chaos in Applied Sciences and Engineering
Year: 2003
Volume: 13
Issue: 12
Pages: 3783-3789
ISSN (print): 0218-1274
ISSN (electronic):
Publisher: World Scientific Publishing