Toggle Main Menu Toggle Search

Open Access padlockePrints

Orthotopic heart transplantation with concurrent aortic valve replacement and coronary artery bypass grafting

Lookup NU author(s): Professor John Dark

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

We report a case of successful orthotopic heart transplantation of a donor heart with normal ventricular function, 2-vessel coronary artery disease, and a bicuspid aortic valve, which required concurrent aortic valve replacement and coronary artery bypass grafting, In confronting the disparities in demand and supply, we must consider the so-called marginally acceptable heart for either critically ill recipients or those who may be disadvantaged on the waiting list.


Publication metadata

Author(s): Dark JH; Rao JN; Prendergast B

Publication type: Article

Publication status: Published

Journal: Journal of Heart and Lung Transplantation

Year: 2000

Volume: 19

Issue: 9

Pages: 897-899

ISSN (print): 1053-2498

ISSN (electronic): 1557-3117

Publisher: Elsevier

URL: http://dx.doi.org/10.1016/S1053-2498(00)00158-3

DOI: 10.1016/S1053-2498(00)00158-3


Altmetrics

Altmetrics provided by Altmetric


Share