Toggle Main Menu Toggle Search

Open Access padlockePrints

Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CT

Lookup NU author(s): Dr Ivan Zammit-Maempel, Simon Willis

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

CT has become an established examination in the evaluation of the paranasal sinuses. Until recently this was achieved by the direct coronal technique on conventional and single slice helical scanners. With the advent of multislice technology, thin slice axial CT with excellent coronal and sagittal reconstructions is now the norm. We describe a study designed to evaluate the radiation dose to the lens of the eye and thyroid gland in the axial and coronal planes on a Siemens Volume Zoom quad slice scanner at 140 kV and effective mAs of 100 using 1 mm collimation. Thermoluminescent dosimeters were placed on the eyelid and thyroid gland of 29 patients scanned axially in the supine position and a further 28 patients scanned coronally in the prone position with gantry tilt. The results show mean doses of 35.1 mGy (lens) and 2.9 mGy (thyroid gland) in the coronal plane compared with 24.5 mGy (lens) and 1.4 mGy (thyroid gland) in the axial plane. Results obtained from a head phantom and from using the ImPACT CT dose calculator were comparable. The kV and mAs were then reduced to 120 and 40, respectively, and the axial study repeated using the head phantom and predicted doses using the ImPACT CT dose calculator. The low dose scanning technique revealed a lens dose of 9.2 mGy and thyroid dose of 0.4 mGy. The eye dose on a multislice scanner is still substantially less than the threshold dose of 0.5-2 Gy for detectable lens opacities. These results indicate that, in addition to the established perceived advantages of multislice axial sinus CT, i.e. patient comfort, no artefact from dental amalgam and reproducible true coronal images, should be included a decreased radiation dose to both the eye lens and thyroid gland compared with direct coronal scanning.


Publication metadata

Author(s): Zammit-Maempel I, Chadwick CL, Willis SP

Publication type: Article

Publication status: Published

Journal: British Journal of Radiology

Year: 2003

Volume: 76

Issue: 906

Pages: 418-420

ISSN (print): 0007-1285

ISSN (electronic): 1748-880X

Publisher: British Institute of Radiology

URL: http://dx.doi.org/10.1259/bjr/82798696

DOI: 10.1259/bjr/82798696


Altmetrics

Altmetrics provided by Altmetric


Share