Toggle Main Menu Toggle Search

Open Access padlockePrints

The differences between bisecting and off-center cuts of the aortic root: The three-dimensional anatomy of the aortic root reconstructed from the living heart

Lookup NU author(s): Professor Bob Anderson

Downloads

Full text for this publication is not currently held within this repository. Alternative links are provided below where available.


Abstract

© 2017, Wiley Periodicals, Inc. Background: It is axiomatic that the diameter of the virtual basal ring of the aortic root, which is elliptical rather than circular, will differ when assessed using between bisecting as opposed to off-center cuts. Such differences, however, which pertain directly to echocardiographic assessments of the so-called valvar annulus, have yet to be systematically explored. Methods: We retrospectively analyzed 30 patients undergoing coronary computed tomographic angiography, measuring the virtual basal ring diameter using routine multiplanar reconstructions. We made orthogonal bisecting cuts from the nadir of the hinge of the right coronary aortic leaflet to the center of the opposite inter-leaflet fibrous triangle between the noncoronary and left coronary aortic leaflets. We compared these measurements with orthogonal off-center cuts made through the nadirs of the hinges of the adjacent leaflets. Results: The measured diameter of the virtual basal ring was significantly longer when measured using the bisecting cut as opposed to all off-center cuts (mean difference: 1.35±1.34 mm, P<.0001; 0.77±0.95 mm, P=.0001, respectively). The measured diameters of the sinuses of Valsalva, in contrast, were significantly shorter when measured using the bisecting cut (mean difference: −3.24±1.38 mm, P<.0001; −2.86±1.61 mm, P<.0001). Conclusions: There are significant differences in the diameters of the aortic root, which represent the echocardiographic annulus, when measured using bisecting as opposed to off-center cuts. Account should be taken of these differences when using cross-sectional echocardiographic measurements to assess the dimensions of the aortic root.


Publication metadata

Author(s): Mori S, Anderson RH, Tahara N, Izawa Y, Toba T, Fujiwara S, Shimoyama S, Watanabe Y, Nishii T, Kono AK, Takahashi S, Hirata K-I

Publication type: Article

Publication status: Published

Journal: Echocardiography

Year: 2017

Volume: 34

Issue: 3

Pages: 453-461

Print publication date: 01/03/2017

Online publication date: 03/02/2017

Acceptance date: 02/04/2016

ISSN (print): 0742-2822

ISSN (electronic): 1540-8175

Publisher: Wiley Periodicals, Inc.

URL: https://doi.org/10.1111/echo.13468

DOI: 10.1111/echo.13468


Altmetrics

Altmetrics provided by Altmetric