Dr Susan Scholes Dr David Greenwood Dr Ilias Sarantakos Professor Sara Walker
| System stress with expanded use of interconnectors in the transition to net-zero | 2023 |
|
Professor Andrea Dolfini Dr Susan Scholes Professor Tom Joyce
| Testing the efficiency of Bronze Age axes: An interdisciplinary experiment | 2023 |
|
Dr Emma Ritchie Dr Susan Scholes Raghu Sidaginamale Professor David Deehan Professor Tom Joyce et al. | A comparative surface topographical analysis of explanted total knee replacement prostheses: Oxidised zirconium vs cobalt chromium femoral components | 2017 |
|
Dr Susan Scholes Benjamin Hunt David Langton Professor Tom Joyce
| Explant analysis of the Biomet Magnum/ReCap metal-on-metal hip joint | 2017 |
|
David Langton Dr Peter Avery Dr Martin Bone Professor David Deehan James Holland et al. | Investigation of Taper Failure in a Contemporary Metal-on-Metal Hip Arthroplasty System Through Examination of Unused and Explanted Prostheses | 2017 |
|
Dr Susan Scholes Dr Andrew Naylor Professor Tom Joyce
| Potential synthetic biolubricant as an alternative to bovine serum | 2016 |
|
Dr Simon Smith Dr Susan Scholes Emeritus Professor Garth Johnson Professor Tom Joyce
| In vitro wear testing of a contemporary design of reverse shoulder prosthesis | 2015 |
|
Dr Richard Holleyman Dr Susan Scholes Professor Tom Joyce Professor David Deehan
| Changes in surface topography at the TKR backside articulation following in-vivo service: A retrieval analysis | 2015 |
|
Dr Martin Bone Raghu Sidaginamale James Lord Dr Susan Scholes Professor Tom Joyce et al. | Determining material loss from the femoral stem trunnion in hip arthroplasty using a coordinate measuring machine | 2015 |
|
Dr Susan Scholes
| Retrieval analysis of alumina ceramic-on-ceramic bearing couples | 2014 |
|
Dr Susan Scholes Professor Tom Joyce
| Ceramic-On-Ceramic Joints: A Suitable Alternative Material Combination? | 2013 |
|
Dr Susan Scholes
| Does surface wettability influence the friction and wear of large-diameter CoCrMo alloy hip resurfacings? | 2013 |
|
Dr Susan Scholes Professor Tom Joyce
| In vitro tests of substitute lubricants for wear testing orthopaedic biomaterials | 2013 |
|
Dr Susan Scholes Dr Emma Ritchie Professor Tom Joyce
| Topographical analysis of the femoral components of ex vivo total knee replacements | 2013 |
|
Dr Susan Scholes
| The wear performance of PEEK-OPTIMA based self-mating couples | 2010 |
|
Dr Susan Scholes
| Compliant layer bearings in artificial joints. Part II: Simulator and fatigue testing to assess the durability of the interface between an elastomeric layer and a rigid substrate | 2009 |
|
Dr Susan Scholes
| Pitch-based CFR-PEEK-OPTIMA assessed as a bearing material in a mobile bearing unicondylar knee joint | 2009 |
|
Dr Susan Scholes
| Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials | 2009 |
|
Dr Susan Scholes
| Compliant layer bearings in artificial joints Part I: The effects of different manufacturing techniques on the interface strength between an elastomeric layer and a rigid substrate | 2008 |
|
Dr Susan Scholes
| Compliant layer tibial bearing inserts: friction testing of different materials and designs for a new generation of prosthesis that mimics the natural joint | 2008 |
|
Dr Susan Scholes
| Tribological assessment of a flexible CFR-PEEK acetabular cup articulating against an alumina femoral head | 2008 |
|
Dr Susan Scholes
| Laboratory studies on the tribology of hard bearing hip prostheses: ceramic on ceramic and metal on metal | 2007 |
|
Dr Susan Scholes
| Polyurethane unicondylar knee prostheses: simulator wear tests and lubrication studies | 2007 |
|
Dr Susan Scholes
| The wear properties of CFR-PEEK articulating against ceramic assessed on a multidirectional pin-on-plate machine | 2007 |
|
Dr Susan Scholes
| Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint | 2006 |
|
Dr Susan Scholes
| The effect of ‘running-in’ on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies | 2006 |
|
Dr Susan Scholes
| The effect of proteins on the friction and lubrication of artificial joints | 2006 |
|
Dr Susan Scholes
| The tribology of metal-on-metal total hip replacements | 2006 |
|
Dr Susan Scholes
| Design aspects of compliant, soft layer bearings for an experimental hip prosthesis | 2005 |
|
Dr Susan Scholes
| The effect of bone cement particles on the friction of polyethylene and polyurethane knee bearings | 2004 |
|
Dr Susan Scholes
| Relative movement between Kinemax Plus tibial inserts and the tibial base-plates | 2003 |
|
Dr Susan Scholes Dr Simon Smith
| The lubrication and friction of conventional UHMWPE, novel compliant layer and hard bearing surfaces for use in total hip prostheses | 2002 |
|
Dr Susan Scholes
| Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples | 2001 |
|
Dr Susan Scholes
| The wear of metal-on-metal total hip prostheses measured in a hip simulator | 2001 |
|
Dr Susan Scholes
| A frictional study of total hip joint replacements | 2000 |
|
Professor Tom Joyce Dr Susan Scholes
| A multi-directional wear screening device and preliminary results of UHMWPE articulating against stainless steel | 2000 |
|
Dr Susan Scholes
| Comparison of friction and lubrication of different hip prostheses | 2000 |
|
Dr Susan Scholes
| The effects of material combination and lubricant on the friction of total hip prostheses | 2000 |
|